Model | OPP-10F | OPP-15F | OPP-20F | OPP-30F | OPP-40F | OPP-50F | OPP-60F | OPP-75F | |
Power (kw) | 7.5 | 11 | 15 | 22 | 30 | 37 | 45 | 55 | |
Horsepower (hp) | 10 | 15 | 20 | 30 | 40 | 50 | 60 | 75 | |
Air displacement/ Working pressure (M³/Min. / bar) |
1.2 / 7 | 1.6 / 7 | 2.5 / 7 | 3.8 / 7 | 5.3 / 7 | 6.8 / 7 | 7.4 / 7 | 10.0 / 7 | |
1.1 / 8 | 1.5/8 | 2.3/8 | 3.6 / 8 | 5.0 / 8 | 6.2 / 8 | 7.0 / 8 | 9.2 / 8 | ||
0.9 / 10 | 1.3 / 10 | 2.1 / 10 | 3.2 / 10 | 4.5 / 10 | 5.6 / 10 | 6.2 / 10 | 8.5 / 10 | ||
0.8 / 12 | 1.1 / 12 | 1.9 / 12 | 2.7 / 12 | 4.0 / 12 | 5.0 / 12 | 5.6 / 12 | 7.6 / 12 | ||
Air out let diameter |
DN20 | DN25 | DN25 | DN25 | DN40 | DN40 | DN40 | DN50 | |
Lubricating oil volume (L) | 10 | 16 | 16 | 18 | 30 | 30 | 30 | 65 | |
Noise level dB(A) | 60±2 | 62±2 | 62±2 | 64±2 | 66±2 | 66±2 | 66±2 | 68±2 | |
Driven method | Direct driven | ||||||||
Type | Fixed Speed | ||||||||
Start method | Υ-Δ | ||||||||
Length (mm) | 950 | 1150 | 1150 | 1350 | 1500 | 1500 | 1500 | 1900 | |
Width (mm) | 670 | 820 | 820 | 920 | 1020 | 1020 | 1020 | 1260 | |
Height (mm) | 1030 | 1130 | 1130 | 1230 | 1310 | 1310 | 1310 | 1600 | |
Weight (kg) | 250 | 400 | 400 | 550 | 700 | 750 | 800 | 1750 |
Model | OPP-100F | OPP-125F | OPP-150F | OPP-175F | OPP-200F | OPP-275F | OPP-350F | |
Power (kw) | 75.0 | 90 | 110 | 132 | 160 | 200 | 250 | |
Horsepower (hp) | 100 | 125 | 150 | 175 | 200 | 275 | 350 | |
Air displacement/ Working pressure (M³/Min. / bar) |
13.4 / 7 | 16.2 / 7 | 21.0 / 7 | 24.5 / 7 | 32.4 / 7 | 38.2 / 7 | 45.5 / 7 | |
12.6 / 8 | 15.0 / 8 | 19.8 / 8 | 23.2 / 8 | 30.2 / 8 | 36.9 / 8 | 43 / 8 | ||
11.2 / 10 | 13.8 / 10 | 17.4 / 10 | 20.5 / 10 | 26.9 / 10 | 33/ / 10 | 38.9 / 10 | ||
10.0 / 12 | 12.3 / 12 | 14.8 / 12 | 17.4 / 12 | 23 / 12 | 28.5 / 12 | 36 / 12 | ||
Air out let diameter |
DN50 | DN50 | DN65 | DN65 | DN75 | DN90 | DN90 | |
Lubricating oil volume (L) | 65 | 72 | 90 | 90 | 110 | 130 | 150 | |
Noise level dB(A) | 68±2 | 70±2 | 70±2 | 70±2 | 75±2 | 85±2 | 85±2 | |
Driven method | Direct driven | |||||||
Type | Fixed Speed | |||||||
Start method | Υ-Δ | |||||||
Length (mm) | 1900 | 2450 | 2450 | 2450 | 2760 | 2760 | 2760 | |
Width (mm) | 1260 | 1660 | 1660 | 1660 | 1800 | 1800 | 1800 | |
Height (mm) | 1600 | 1700 | 1700 | 1700 | 2100 | 2100 | 2100 | |
Weight (kg) | 1850 | 1950 | 2200 | 2500 | 2800 | 3100 | 3500 |
Model | OPP-10PV | OPP-15PV | OPP-20PV | OPP-30PV | OPP-40PV | OPP-50PV | OPP-60PV | OPP-75PV | |
Power (kw) | 7.5 | 11 | 15 | 22 | 30 | 37 | 45 | 55 | |
Horsepower (hp) | 10 | 15 | 20 | 30 | 40 | 50 | 60 | 75 | |
Air displacement/ Working pressure (M³/Min. / bar) |
1.2 / 7 | 1.6 / 7 | 2.5 / 7 | 3.8 / 7 | 5.3 / 7 | 6.8 / 7 | 7.4 / 7 | 10.0 / 7 | |
1.1 / 8 | 1.5/8 | 2.3/8 | 3.6 / 8 | 5.0 / 8 | 6.2 / 8 | 7.0 / 8 | 9.2 / 8 | ||
0.9 / 10 | 1.3 / 10 | 2.1 / 10 | 3.2 / 10 | 4.5 / 10 | 5.6 / 10 | 6.2 / 10 | 8.5 / 10 | ||
0.8 / 12 | 1.1 / 12 | 1.9 / 12 | 2.7 / 12 | 4.0 / 12 | 5.0 / 12 | 5.6 / 12 | 7.6 / 12 | ||
Air out let diameter |
DN20 | DN25 | DN25 | DN25 | DN40 | DN40 | DN40 | DN50 | |
Lubricating oil volume (L) | 10 | 16 | 16 | 18 | 30 | 30 | 30 | 65 | |
Noise level dB(A) | 60±2 | 62±2 | 62±2 | 64±2 | 66±2 | 66±2 | 66±2 | 68±2 | |
Driven method | Direct driven | ||||||||
Type | PM VSD | ||||||||
Start method | Variable frequency start | ||||||||
Length (mm) | 950 | 1150 | 1150 | 1350 | 1500 | 1500 | 1500 | 1900 | |
Width (mm) | 670 | 820 | 820 | 920 | 1020 | 1020 | 1020 | 1260 | |
Height (mm) | 1030 | 1130 | 1130 | 1230 | 1310 | 1310 | 1310 | 1600 | |
Weight (kg) | 250 | 400 | 400 | 550 | 700 | 750 | 800 | 1750 |
Model | OPP-100PV | OPP-125F | OPP-150PV | OPP-175PV | OPP-200PV | OPP-275PV | OPP-350PV | |
Power (kw) | 75.0 | 90 | 110 | 132 | 160 | 200 | 250 | |
Horsepower (hp) | 100 | 125 | 150 | 175 | 200 | 275 | 350 | |
Air displacement/ Working pressure (M³/Min. / bar) |
13.4 / 7 | 16.2 / 7 | 21.0 / 7 | 24.5 / 7 | 32.4 / 7 | 38.2 / 7 | 45.5 / 7 | |
12.6 / 8 | 15.0 / 8 | 19.8 / 8 | 23.2 / 8 | 30.2 / 8 | 36.9 / 8 | 43 / 8 | ||
11.2 / 10 | 13.8 / 10 | 17.4 / 10 | 20.5 / 10 | 26.9 / 10 | 33/ / 10 | 38.9 / 10 | ||
10.0 / 12 | 12.3 / 12 | 14.8 / 12 | 17.4 / 12 | 23 / 12 | 28.5 / 12 | 36 / 12 | ||
Air out let diameter |
DN50 | DN50 | DN65 | DN65 | DN75 | DN90 | DN90 | |
Lubricating oil volume (L) | 65 | 72 | 90 | 90 | 110 | 130 | 150 | |
Noise level dB(A) | 68±2 | 70±2 | 70±2 | 70±2 | 75±2 | 85±2 | 85±2 | |
Driven method | Direct driven | |||||||
Type | PM VSD | |||||||
Start method | Variable frequency start | |||||||
Length (mm) | 1900 | 2450 | 2450 | 2450 | 2760 | 2760 | 2760 | |
Width (mm) | 1260 | 1660 | 1660 | 1660 | 1800 | 1800 | 1800 | |
Height (mm) | 1600 | 1700 | 1700 | 1700 | 2100 | 2100 | 2100 | |
Weight (kg) | 1850 | 1950 | 2200 | 2500 | 2800 | 3100 | 3500 |
1. Adopts PLC multilanguage control system, beautiful and intuitive interface, easy to operate function, operators can quickly and easily adjust the compressor.
2. 14 protection functions such as overload protection, short circuit protection, reverse protection, low temperature protection, high voltage protection, etc. to fully protect the unit.
3. The advanced microcomputer control drive system realizes itelligent control, air volume variable speed control, automatic adjustment of load start and soft start. Inelligent dynamic control, dynamic display of the working status of each component of the compressor, visual pressure, temperature, current working curve, etc.
4. Large memory and equipped with printer interface; It can use computer remote monitoring or multiple linkage control between air compressors.
1. The motor adopts a well-known brand high-performance motor. The permanent magnet synchronous motor (PM motor) adopts high-performance permanent magnets, which do not lose magnetism under 200°, and have a service life of up to 15 years.
2. The stator coil adopts the special anti-halation enameled wire for frequency converter, which has excellent insulation performance and longer service life.
3. The motor has a temperature protection function, the motor has a wide range of speed regulation, high precision volume adjustment, and a wide range. Small size, low noise, large overcurrent, significantly improved reliability.
4. Protection class IP55, insulation class F, effectively protect the motor, increase the service life of the motor, and the efficiency is 5%-7% higher than similar products.
1. Intake valve is the core component to control the air intake of the air compressor.
2. Adopting the world famous brand air intake valve, it can automatically adjust theair volume by 0-100% according to the requirement of the system air quantity. It promises small pressure loss, stable action and long life consequently reduced operating costs.