Model | OPP-10F | OPP-15F | OPP-20F | OPP-30F | OPP-40F | OPP-50F | OPP-60F | OPP-75F | |
Power (kw) | 7.5 | 11 | 15 | 22 | 30 | 37 | 45 | 55 | |
Horsepower (hp) | 10 | 15 | 20 | 30 | 40 | 50 | 60 | 75 | |
Air displacement/ Working pressure (M³/Min. / bar) |
1.2 / 7 | 1.6 / 7 | 2.5 / 7 | 3.8 / 7 | 5.3 / 7 | 6.8 / 7 | 7.4 / 7 | 10.0 / 7 | |
1.1 / 8 | 1.5/8 | 2.3/8 | 3.6 / 8 | 5.0 / 8 | 6.2 / 8 | 7.0 / 8 | 9.2 / 8 | ||
0.9 / 10 | 1.3 / 10 | 2.1 / 10 | 3.2 / 10 | 4.5 / 10 | 5.6 / 10 | 6.2 / 10 | 8.5 / 10 | ||
0.8 / 12 | 1.1 / 12 | 1.9 / 12 | 2.7 / 12 | 4.0 / 12 | 5.0 / 12 | 5.6 / 12 | 7.6 / 12 | ||
Air out let diameter |
DN20 | DN25 | DN25 | DN25 | DN40 | DN40 | DN40 | DN50 | |
Lubricating oil volume (L) | 10 | 16 | 16 | 18 | 30 | 30 | 30 | 65 | |
Noise level dB(A) | 60±2 | 62±2 | 62±2 | 64±2 | 66±2 | 66±2 | 66±2 | 68±2 | |
Driven method | Direct driven | ||||||||
Type | Fixed Speed | ||||||||
Start method | Υ-Δ | ||||||||
Length (mm) | 950 | 1150 | 1150 | 1350 | 1500 | 1500 | 1500 | 1900 | |
Width (mm) | 670 | 820 | 820 | 920 | 1020 | 1020 | 1020 | 1260 | |
Height (mm) | 1030 | 1130 | 1130 | 1230 | 1310 | 1310 | 1310 | 1600 | |
Weight (kg) | 250 | 400 | 400 | 550 | 700 | 750 | 800 | 1750 |
Model | OPP-100F | OPP-125F | OPP-150F | OPP-175F | OPP-200F | OPP-275F | OPP-350F | |
Power (kw) | 75.0 | 90 | 110 | 132 | 160 | 200 | 250 | |
Horsepower (hp) | 100 | 125 | 150 | 175 | 200 | 275 | 350 | |
Air displacement/ Working pressure (M³/Min. / bar) |
13.4 / 7 | 16.2 / 7 | 21.0 / 7 | 24.5 / 7 | 32.4 / 7 | 38.2 / 7 | 45.5 / 7 | |
12.6 / 8 | 15.0 / 8 | 19.8 / 8 | 23.2 / 8 | 30.2 / 8 | 36.9 / 8 | 43 / 8 | ||
11.2 / 10 | 13.8 / 10 | 17.4 / 10 | 20.5 / 10 | 26.9 / 10 | 33/ / 10 | 38.9 / 10 | ||
10.0 / 12 | 12.3 / 12 | 14.8 / 12 | 17.4 / 12 | 23 / 12 | 28.5 / 12 | 36 / 12 | ||
Air out let diameter |
DN50 | DN50 | DN65 | DN65 | DN75 | DN90 | DN90 | |
Lubricating oil volume (L) | 65 | 72 | 90 | 90 | 110 | 130 | 150 | |
Noise level dB(A) | 68±2 | 70±2 | 70±2 | 70±2 | 75±2 | 85±2 | 85±2 | |
Driven method | Direct driven | |||||||
Type | Fixed Speed | |||||||
Start method | Υ-Δ | |||||||
Length (mm) | 1900 | 2450 | 2450 | 2450 | 2760 | 2760 | 2760 | |
Width (mm) | 1260 | 1660 | 1660 | 1660 | 1800 | 1800 | 1800 | |
Height (mm) | 1600 | 1700 | 1700 | 1700 | 2100 | 2100 | 2100 | |
Weight (kg) | 1850 | 1950 | 2200 | 2500 | 2800 | 3100 | 3500 |
1. The motor adopts a well-known brand high-performance motor. The permanent magnet synchronous motor (PM motor) adopts high-performance permanent magnets, which do not lose magnetism under 200°, and have a service life of up to 15 years.
2. The stator coil adopts the special anti-halation enameled wire for frequency converter, which has excellent insulation performance and longer service life.
3. The motor has a temperature protection function, the motor has a wide range of speed regulation, high precision volume adjustment, and a wide range. Small size, low noise, large overcurrent, significantly improved reliability.
4. Protection class IP55, insulation class F, effectively protect the motor, increase the service life of the motor, and the efficiency is 5%-7% higher than similar products.
1. The fan uses a large fan design to effectively enhance the fan's heat dissipation effect.The motor adopts a special intermnal design to adapt to harsh working conditions.
2. The fan motor adopts specal winding and high protection grade design to adapt to harsh working conditions.
3. The fan is controlld by the controller to realie the automatic start and stop function, which efctively maintains the normal working temperature of the air compressor lubricant.
1. The heat exchanger uses high-quality raw materials and a unique intemal channel design, which increases the heat exchange area and can effectively dissipate heat for the air compressor.
2. The inner wall of the heat exchanger is treated with corrosion protection to increase the service life of the heat exchanger and increase the heat transfer effect.
3. The radiator has passed the strict factory test, and the quality is reliable, which efetively prevents the high temperature of the air compressor and increases the service life of the machine.